Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev Bras Ortop (Sao Paulo) ; 55(4): 410-414, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32904805

RESUMO

Objective To evaluate different decontaminants for tendon grafts, proposing an antiseptic protocol for contaminated grafts. Methods A total of 25 patients were tissue donors for the study. Each participant donated a 2.5-cm tendon sample, which was divided into 5 fragments with 5 mm each during anterior cruciate ligament (ACL) reconstruction surgery. The collected material was divided into 5 groups, totaling 125 samples. In total, four fragments of each patient were placed on the operating room floor for one minute for contamination, simulating the fall of the graft on the floor during surgery. The other fragment was immediately placed in a sterile container (group 1). One of the contaminated fragments was placed in the sterile container without being previously immersed in decontaminating solution (group 2). The remaining fragments were immersed for ten minutes in decontaminating solution: 0.5% chlorhexidine (group 3), 0.9% saline (group 4) and 0.55% ortho-phthalaldehyde (group 5), and, after this time, they were individually placed in a sterile container. The samples from the 5 groups were submitted to microbiological examination. Results Bacteria were detected in 26% of the total samples in the microbiological tests, and in group 1 there was no growth of microorganisms. In group 2, bacterial growth was observed in 16 samples. Considering the evaluation of test groups 3, 4 and 5, the percentage of decontamination was higher than the growth of microorganisms in the respective cultures. Conclusion The protocol suggested by the study showed that intraoperative graft decontamination is possible.

2.
Rev. bras. ortop ; 55(4): 410-414, Jul.-Aug. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1138056

RESUMO

Abstract Objective To evaluate different decontaminants for tendon grafts, proposing an antiseptic protocol for contaminated grafts. Methods A total of 25 patients were tissue donors for the study. Each participant donated a 2.5-cm tendon sample, which was divided into 5 fragments with 5 mm each during anterior cruciate ligament (ACL) reconstruction surgery. The collected material was divided into 5 groups, totaling 125 samples. In total, four fragments of each patient were placed on the operating room floor for one minute for contamination, simulating the fall of the graft on the floor during surgery. The other fragment was immediately placed in a sterile container (group 1). One of the contaminated fragments was placed in the sterile container without being previously immersed in decontaminating solution (group 2). The remaining fragments were immersed for ten minutes in decontaminating solution: 0.5% chlorhexidine (group 3), 0.9% saline (group 4) and 0.55% ortho-phthalaldehyde (group 5), and, after this time, they were individually placed in a sterile container. The samples from the 5 groups were submitted to microbiological examination. Results Bacteria were detected in 26% of the total samples in the microbiological tests, and in group 1 there was no growth of microorganisms. In group 2, bacterial growth was observed in 16 samples. Considering the evaluation of test groups 3, 4 and 5, the percentage of decontamination was higher than the growth of microorganisms in the respective cultures. Conclusion The protocol suggested by the study showed that intraoperative graft decontamination is possible.


Resumo Objetivo Avaliar diferentes descontaminantes para enxertos de tendões, propondo um protocolo de antissepsia para o enxerto contaminado. Métodos Um total de 25 pacientes foram doadores de tecido para o estudo. Cada participante doou uma amostra de 2,5 cm de tendão, a qual foi dividida em 5 fragmentos de 5 mm durante cirurgia de reconstrução do ligamento cruzado anterior (LCA). O material coletado foi dividido em 5 grupos, totalizando 125 amostras. Ao todo, quatro fragmentos de cada paciente foram colocados sobre o piso da sala cirúrgica, durante um minuto, para contaminação, simulando a queda do enxerto no chão durante o ato operatório. O outro fragmento foi, imediatamente, colocado em um recipiente esterilizado (grupo 1). Um dos fragmentos contaminados foi colocado no recipiente esterilizado sem ser previamente imerso em solução descontaminante (grupo 2). Os demais fragmentos foram imersos, por dez minutos, em solução descontaminante: clorexidina 0,5% (grupo 3), soro fisiológico 0,9% (grupo 4) e ortoftaldeído 0,55% (grupo 5), e, após esse tempo, foram colocados individualmente em um recipiente esterilizado. As amostras dos 5 grupos foram submetidas a exame microbiológico. Resultados Houve detecção de bactérias em 26% do total de amostras nos testes microbiológicos, sendo que no grupo 1 não houve crescimento de micro-organismos. No grupo 2, observou-se crescimento bacteriano em 16 amostras. Avaliando-se os grupos de teste 3, 4 e 5, o percentual de descontaminação foi superior ao crescimento de micro-organismos nas respectivas culturas. Conclusão O protocolo sugerido pelo estudo mostrou que é possível a descontaminação transoperatória do enxerto.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Salas Cirúrgicas , Tendões , Doadores de Tecidos , Clorexidina , Antissepsia , Descontaminação , Ligamento Cruzado Anterior , Transplantes , Autoenxertos
3.
Rev. bras. ortop ; 53(4): 421-426, July-Aug. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-959154

RESUMO

ABSTRACT Objective: To evaluate the morphology of the anterior cruciate ligament (ACL) femoral insertion in order to describe its anatomical features and insertion site location, with the aim of verifying if the ACL femoral insertion has individual characteristics and to provide information for appropriate femoral tunnel placement on anatomic ACL reconstruction. Methods: Sixteen knees obtained from amputations were studied. The ACL femoral bundles and insertion shape were observed macroscopically, and the ligaments insertion length and thickness were measured with a digital caliper. The distances between the limits of the ligament to the articular cartilage, and the measurement of the area of insertion were checked using ImageJ software. Results: The ACL femoral insertion site was eccentric, closer to the deep condyle cartilage. In ten knees (62.5%), the ACL femoral insertion was oval; the mean length of the insertion was 16.4 mm, varying from 11.3 to 19.3 mm, the mean thickness varied from 7.85 to 11.23 mm, and the mean area of the insertion was 99.7 mm2, varying from 80.9 a 117.2 mm2. The mean distances between the limits of the ligament to the superficial, deep, and inferior articular cartilage were 9.77 ± 1.21, 2.60 ± 1.20, and 1.86 ± 1.15 mm, respectively. Conclusion: There was a 30% to 40% difference between the minimum and maximum results of measurements of ACL femoral insertion length, thickness, and area demonstrating an important individual variation. The insertion site was eccentric, closer to the deep cartilage of the lateral femoral condyle.


RESUMO Objetivo: Avaliar os aspectos morfológicos da inserção femoral do ligamento cruzado anterior (LCA) para definir suas características anatômicas e a localização de seu sítio de inserção, com a finalidade de verificar se essa inserção tem características individuais e para prover informações para o posicionamento adequado do túnel femoral na reconstrução anatômica do LCA. Métodos: Foram examinados 16 joelhos originados de amputações. Nesses, foram observados macroscopicamente o número de bandas e o formato das inserções ligamentares. Foram medidos, com um paquímetro digital, o comprimento e a espessura dessas inserções. As distâncias entre os limites do ligamento e a cartilagem articular e a medida da área de inserção ligamentar foram avaliadas com o software ImageJ. Resultados: A localização do sítio de inserção ligamentar do LCA no côndilo femoral lateral foi excêntrica, mais próxima da cartilagem condilar profunda. Em dez joelhos (62,5%) as inserções foram ovais; o comprimento médio das inserções foi de 16,4 mm, variou de 11,3 a 19,3 mm; a espessura variou de 7,85 a 11,23 mm (média de 9,62). A área média das inserções foi de 99,7 mm2, variou de 80,9 a 117,2 mm2. As distâncias médias entre os limites do ligamento até a cartilagem articular superficial, profunda e inferior foram, respectivamente, 9,77 ± 1,21; 2,60 ± 1,20 e 1,86 ± 1,15. Conclusão: Houve uma diferença de 30% a 40% entre os resultados mínimo e máximo das mensurações do comprimento, da espessura e da área das inserções femorais do LCA, evidenciou uma variação individual importante. O sítio de inserção do LCA foi excêntrico, mais próximo da cartilagem articular profunda do côndilo femoral lateral.


Assuntos
Humanos , Masculino , Feminino , Ligamento Cruzado Anterior , Procedimentos Ortopédicos , Fêmur
4.
Rev Bras Ortop ; 53(4): 421-426, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30027073

RESUMO

OBJECTIVE: To evaluate the morphology of the anterior cruciate ligament (ACL) femoral insertion in order to describe its anatomical features and insertion site location, with the aim of verifying if the ACL femoral insertion has individual characteristics and to provide information for appropriate femoral tunnel placement on anatomic ACL reconstruction. METHODS: Sixteen knees obtained from amputations were studied. The ACL femoral bundles and insertion shape were observed macroscopically, and the ligaments insertion length and thickness were measured with a digital caliper. The distances between the limits of the ligament to the articular cartilage, and the measurement of the area of insertion were checked using ImageJ software. RESULTS: The ACL femoral insertion site was eccentric, closer to the deep condyle cartilage. In ten knees (62.5%), the ACL femoral insertion was oval; the mean length of the insertion was 16.4 mm, varying from 11.3 to 19.3 mm, the mean thickness varied from 7.85 to 11.23 mm, and the mean area of the insertion was 99.7 mm2, varying from 80.9 a 117.2 mm2. The mean distances between the limits of the ligament to the superficial, deep, and inferior articular cartilage were 9.77 ± 1.21, 2.60 ± 1.20, and 1.86 ± 1.15 mm, respectively. CONCLUSION: There was a 30% to 40% difference between the minimum and maximum results of measurements of ACL femoral insertion length, thickness, and area demonstrating an important individual variation. The insertion site was eccentric, closer to the deep cartilage of the lateral femoral condyle.


OBJETIVO: Avaliar os aspectos morfológicos da inserção femoral do ligamento cruzado anterior (LCA) para definir suas características anatômicas e a localização de seu sítio de inserção, com a finalidade de verificar se essa inserção tem características individuais e para prover informações para o posicionamento adequado do túnel femoral na reconstrução anatômica do LCA. MÉTODOS: Foram examinados 16 joelhos originados de amputações. Nesses, foram observados macroscopicamente o número de bandas e o formato das inserções ligamentares. Foram medidos, com um paquímetro digital, o comprimento e a espessura dessas inserções. As distâncias entre os limites do ligamento e a cartilagem articular e a medida da área de inserção ligamentar foram avaliadas com o software ImageJ. RESULTADOS: A localização do sítio de inserção ligamentar do LCA no côndilo femoral lateral foi excêntrica, mais próxima da cartilagem condilar profunda. Em dez joelhos (62,5%) as inserções foram ovais; o comprimento médio das inserções foi de 16,4 mm, variou de 11,3 a 19,3 mm; a espessura variou de 7,85 a 11,23 mm (média de 9,62). A área média das inserções foi de 99,7 mm2, variou de 80,9 a 117,2 mm2. As distâncias médias entre os limites do ligamento até a cartilagem articular superficial, profunda e inferior foram, respectivamente, 9,77 ± 1,21; 2,60 ± 1,20 e 1,86 ± 1,15. CONCLUSÃO: Houve uma diferença de 30% a 40% entre os resultados mínimo e máximo das mensurações do comprimento, da espessura e da área das inserções femorais do LCA, evidenciou uma variação individual importante. O sítio de inserção do LCA foi excêntrico, mais próximo da cartilagem articular profunda do côndilo femoral lateral.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...